Table of Contents
Power analysis is a statistical tool used to determine the minimum sample size needed for a study to detect a significant effect. In the context of a one-sample t-test in Stata, power analysis involves calculating the statistical power, which is the probability of correctly rejecting the null hypothesis when it is actually false. This analysis takes into account factors such as sample size, effect size, and alpha level to determine the likelihood of obtaining a significant result. It is an important step in the planning and design of a study as it helps researchers determine the appropriate sample size for their study to ensure accurate and reliable results. In Stata, power analysis for a one-sample t-test can be performed using the appropriate command, which calculates the necessary parameters and provides a power curve to visualize the relationship between sample size and power.
Power Analysis for One-sample t-test | Stata Data Analysis Examples
Examples
Example 1. A company that manufactures light bulbs claims that a particular type of light
bulb will last 850 hours on average with standard deviation of 50. A consumer
protection group thinks that the manufacturer has overestimated the lifespan of
their light bulbs by about 40
hours. How many light bulbs does the consumer protection group have to test in
order to prove their point with reasonable confidence?
Example 2. It has been estimated that the average height of American white male adults
is 70 inches. It has also been postulated that there is a
positive correlation between height and intelligence. If this is true, then the
average height of a white male graduate students on campus
should be greater than the average height of American white male adults
in general. You want to test this theory out by random sampling a small group of
white male graduate students. But you need to know
how small the group can be or how few people that you need to measure
such that you can still prove your point.
Prelude to The Power Analysis
For the power analysis below, we are going to focus on Example 1 testing the
average lifespan of a light bulb. Our first goal is to figure out the number of
light bulbs that need to be tested. That is, we will determine the sample
size for a given a significance level and power. Next, we will reverse the process
and determine the power, given the sample size and the significance
level.
We know so far that the manufacturer claims that the average lifespan of the
light bulb is 850 with the standard deviation of 50, and the consumer protection
group believes that the manufacturer has overestimated by about 40 hours. So
in terms of hypotheses, our null hypothesis is H0 = 850
and our alternative hypothesis is Ha= 810.
The significance level is the probability of a Type I error, that is the
probability of rejecting H0 when it is actually true. We will set it
at the .05 level. The power of the test against Ha is the probability of
that the test rejects H0. We will set it at .90 level.
We are almost ready for our power analysis. But let’s talk about the standard
deviation a little bit. Intuitively, the number of light bulbs we need to test
depends on the variability of the lifespan of these light bulbs. Take an extreme
case where all the light bulbs have exactly the same lifespan. Then we just need
to check a single light bulb to prove our point. Of course, this will never
happen. On the other hand, suppose that some light bulbs last for 1000 hours and some only
last 500 hours. We will have to select quite a few of light bulbs to cover all
the ground. Therefore, the standard deviation for the distribution of the
lifespan of the light bulbs will play an important role in determining the
sample size.
Power Analysis
In Stata, it is fairly straightforward to perform a power analysis for
comparing means. For example, we can use Stata’s power command for our
calculation as shown below. First, we indicate that we have one mean. Next, we specify the two means, the mean for the
null hypothesis and the mean for the alternative hypothesis. Then we specify the desired power (.9) and the
standard deviation for the population. The default significance level (alpha
level) is at .05, so we are not going to specify it.
power onemean 850 810, power(.9) sd(50)
Performing iteration ...
Estimated sample size for a one-sample mean test
t test
H0: m = m0 versus Ha: m != m0
Study parameters:
alpha = 0.0500
power = 0.9000
delta = -0.8000
m0 = 850.0000
ma = 810.0000
sd = 50.0000
Estimated sample size:
N = 19
The result tells us that we need a sample size at least 19
light bulbs to reject H0 under the alternative hypothesis Ha to
have a power of 0.9.
Next, suppose we have a sample of size 10. How much power do we have keeping all of the other
numbers the same? We can use the same program, power, to calculate it.
power onemean 850 810, n(10) sd(50)
Estimated power for a one-sample mean test
t test
H0: m = m0 versus Ha: m != m0
Study parameters:
alpha = 0.0500
N = 10
delta = -0.8000
m0 = 850.0000
ma = 810.0000
sd = 50.0000
Estimated power:
power = 0.6162
You can see that the power is about .62 for a sample size of 10. What then is the power for
sample size of 15?
power onemean 850 810, n(15) sd(50)
Estimated power for a one-sample mean test
t test
H0: m = m0 versus Ha: m != m0
Study parameters:
alpha = 0.0500
N = 15
delta = -0.8000
m0 = 850.0000
ma = 810.0000
sd = 50.0000
Estimated power:
power = 0.8213So now the power is about .82. You could also do it again to find out the power for a
sample size of 20. You’ll probably expect that the power will be greater.
power onemean 850 810, n(20) sd(50)
Estimated power for a one-sample mean test
t test
H0: m = m0 versus Ha: m != m0
Study parameters:
alpha = 0.0500
N = 20
delta = -0.8000
m0 = 850.0000
ma = 810.0000
sd = 50.0000
Estimated power:
power = 0.9239We can also expect that if we specified a lower power or the standard deviation
is smaller, then the sample size should also be smaller. We can experiment with
different values of power and standard deviation as shown below.
power onemean 850 810, power(.8) sd(50)
Performing iteration ...
Estimated sample size for a one-sample mean test
t test
H0: m = m0 versus Ha: m != m0
Study parameters:
alpha = 0.0500
power = 0.8000
delta = -0.8000
m0 = 850.0000
ma = 810.0000
sd = 50.0000
Estimated sample size:
N = 15If the standard deviation is smaller, then the sample size should also go down,
as we discussed before.
power onemean 850 810, power(.8) sd(30)
Performing iteration ...
Estimated sample size for a one-sample mean test
t test
H0: m = m0 versus Ha: m != m0
Study parameters:
alpha = 0.0500
power = 0.8000
delta = -1.3333
m0 = 850.0000
ma = 810.0000
sd = 30.0000
Estimated sample size:
N = 7Discussion
There is another technical assumption, the normality assumption. If the
variable is not normally distributed, a small sample size usually will not have the
power indicated in the results, because those results are calculated using the common method based on the normality assumption. It
might not even be a good idea to do a t-test on such a small sample to begin with
if the normality assumption is in question.
Here is another technical point. What we really need to know is the difference between the two means, not the
individual values. In fact, what really matters is the difference of the means
over the standard deviation. We call this the effect size. For example, we would
get the same power if we subtracted 800 from each mean, changing 850 to 50 and 810 to 10.
power onemean 50 10, power(.9) sd(50)
Performing iteration ...
Estimated sample size for a one-sample mean test
t test
H0: m = m0 versus Ha: m != m0
Study parameters:
alpha = 0.0500
power = 0.9000
delta = -0.8000
m0 = 50.0000
ma = 10.0000
sd = 50.0000
Estimated sample size:
N = 19
If we standardize our variable, we can calculate the means in terms of change
in standard deviations.
power onemean 1 .2, power(.9) sd(1)
Performing iteration ...
Estimated sample size for a one-sample mean test
t test
H0: m = m0 versus Ha: m != m0
Study parameters:
alpha = 0.0500
power = 0.9000
delta = -0.8000
m0 = 1.0000
ma = 0.2000
sd = 1.0000
Estimated sample size:
N = 19
It is usually not an easy task to determine the “true” effect size. We make our best
guess based upon the existing literature, a pilot study or the smallest effect size of interest. A good estimate of the effect size
is the key to a successful power analysis.
See Also
Cite this article
stats writer (2024). What is the power analysis for a one-sample t-test in Stata?. PSYCHOLOGICAL SCALES. Retrieved from https://scales.arabpsychology.com/stats/what-is-the-power-analysis-for-a-one-sample-t-test-in-stata/
stats writer. "What is the power analysis for a one-sample t-test in Stata?." PSYCHOLOGICAL SCALES, 29 Jun. 2024, https://scales.arabpsychology.com/stats/what-is-the-power-analysis-for-a-one-sample-t-test-in-stata/.
stats writer. "What is the power analysis for a one-sample t-test in Stata?." PSYCHOLOGICAL SCALES, 2024. https://scales.arabpsychology.com/stats/what-is-the-power-analysis-for-a-one-sample-t-test-in-stata/.
stats writer (2024) 'What is the power analysis for a one-sample t-test in Stata?', PSYCHOLOGICAL SCALES. Available at: https://scales.arabpsychology.com/stats/what-is-the-power-analysis-for-a-one-sample-t-test-in-stata/.
[1] stats writer, "What is the power analysis for a one-sample t-test in Stata?," PSYCHOLOGICAL SCALES, vol. X, no. Y, ص Z-Z, June, 2024.
stats writer. What is the power analysis for a one-sample t-test in Stata?. PSYCHOLOGICAL SCALES. 2024;vol(issue):pages.